Connection Via Main Distribution Board - Mitel Aastra 470 System Manual

R3.2
Hide thumbs Also See for Aastra 470:
Table of Contents

Advertisement

Installation
4. 6. 2. 1

Connection via main distribution board

Fig. 30
Connection via main distribution board
The interface sockets on the front panel and on the fan-out-panel (FOP) where ap-
plicable are connected with the (main) distribution frame or the patch panels using
either patch cables or prefabricated system cables (see
page
260).
Prefabricated system cable 4 x RJ45
With terminal cards with 16 or more interfaces some or all of the RJ45 sockets are
assigned four-fold on the front panel of the Aastra 470. With this cable they can be
connected without the use of a fan-out-panel (FOP). The cable is 6 m long and at
one extremity has four RJ45 connectors on which all the pins are wired.
Schematic diagram of prefabricated system cable 4  RJ45  8 Pin
Tab. 42
Stranded
Core colour
element
white
blue
1
turquoise
violet
white
orange
2
turquoise
violet
112
Communica-
tion server
NT1
NT1
(Main)
distribution
board
RJ45
Cable desig-
nation
Pin
4
5
3
6
1
1
2
7
8
"Equipment Overview",
Port
Two-wire connection
x.1a
x.1b
x.2a
x.2b
x.3a
x.3b
x.4a
x.4b
Aastra 470 as of R3.2
syd-0337/1.6 – R3.2 – 09.2014

Advertisement

Table of Contents
loading

Table of Contents