5 Parameters
5.5 Digital and analog inputs
1)
P-15
DI1
0, 5,
0 = Locked
10,
1 = Start enable FWD
11, 12
1
0 = Locked
1 = Start enable FWD
2
0 = Locked
1 = Start enable FWD
3
0 = Locked
1 = Start enable FWD
4
0 = Locked
1 = Start enable FWD
6, 7
0 = Locked
1 = Start enable FWD
8, 9
0 = Locked
1 = Start-Enable
Note:
Negative fixed frequencies are inverted it Run REV is selected.
1) FWD switch position only for IP66 degree of protection with local controls
2) REV switch position only for IP66 degree of protection with local controls
3) Button command
102
SmartWire-DT (P-12 = 10)
2)
DI2
DI3/AI2
Not assigned
0 = Setpoint value AI1
1 = Fixed frequency 1
0 = Selected setpoint
0 = Fixed frequency 1
source
1 = Fixed frequency 2
1 = fixed frequency 1/2
DI2
DI3/AI2
Fixed frequency
0
0
FF1 (P-20)
1
0
FF2 (P-21)
0
1
FF3 (P-22)
1
1
FF4 (P-23)
0 = Selected setpoint
External fault
source
0 = Fault
1 = Fixed frequency 1
1 = Enable
0 = Setpoint value AI1
Setpoint value AI2
1 = setpoint value AI2
Not assigned
0 = Selected setpoint source
1 = Fixed frequency 1 (P-20)
0 = FWD
DI3
1 = REV
0
1
0
1
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com
AI1/DI4
Setpoint value AI1
Setpoint value AI1
0 = Fixed
frequency 1 - 4
(P-20 - P-23)
1 = maximum
frequency (P-01)
Setpoint value AI1
Setpoint value AI1
Setpoint value AI1
AI1
Fixed frequency
0
FF1 (P-20)
0
FF2 (P-21)
1
FF3 (P-22)
1
FF4 (P-23)
Notes
4 selectable fixed frequen-
cies:
The analog input will be used
as a digital input.
Switched if:
8 V < V
< 30 V
input
Used to connect an external
thermistor to DI3
Changing between analog
input: 1 and 2
Connection of DI1 and DI2
leads to a quick stop (P-24).
4 selectable fixed frequen-
cies:
The analog input will be used
as a digital input:
Switched if:
8 V < V
< 30 V
input