Eaton PowerXL DC1 Manual page 20

Variable frequency drive
Hide thumbs Also See for PowerXL DC1:
Table of Contents

Advertisement

Catalog number examples
Inscription
Meaning
DC1-124D1FN-A20N
DC1 = DC1 series variable frequency drive
1 = Single-phase mains connection / three-phase motor connection
2 = 230 V mains voltage category (200 - 240 V ±10%)
4D1 = 4.1 A rated operational current (output current)
F = Integrated radio interference suppression filter (RFI, EMC measure)
N = No integrated braking chopper
A = LED display (7-segment) on operating unit
20 = Degree of protection IP20 / NEMA 0
N = basic device
DC1-327DOFB-A66N
DC1 = DC1 series variable frequency drive
3 = Three-phase mains connection / three-phase motor connection
2 = 230 V mains voltage category (200 - 240 V ±10%)
7D0 = 7 A rated operational current (output current)
F = Integrated radio interference suppression filter (RFI, EMC measure)
B = Integrated Brake Chopper. An external braking resistance (optional) is required for
this function.
A = LED display (7-segment) on operating unit
66 = degree of protection IP66 / NEMA 4X
N = basic device
DC1-34024NB-A20N
DC1 = DC1 series variable frequency drive
3 = Three-phase mains connection / three-phase motor connection
4 = 400 V mains voltage category (380 - 480 V ±10%)
024 = 24 A rated operational current (output current)
N = No integrated radio interference suppression filter (RFI)
B = Integrated Brake Chopper. An external braking resistance (optional) is required for
this function.
A = LED display (7-segment) on operating unit
20 = Degree of protection IP20 / NEMA 0
N = basic device
DC1-342D2FN-A6SN
DC1 = DC1 series variable frequency drive
3 = Three-phase mains connection / three-phase motor connection
4 = 400 V mains voltage category (380 - 480 V ±10%)
2D2 = 2.2 A rated operational current (output current)
F = Integrated radio interference suppression filter (RFI, EMC measure)
N = No integrated braking chopper
A = LED display (7-segment) on operating unit
6S = Degree of protection IP66 / NEMA 4X with switches (mains switch, enable/phase
sequence, potentiometer) for local control
N = basic device
1) In the case of variable frequency drives without an integrated EMC filter, external measures (e.g., external radio
interference suppression filters) must be used for operation in accordance with IEC/EN 61800-3 in order to
comply with the relevant limits concerning electromagnetic compatibility (EMC).
In accordance with IEC/EN 61800-3, an external radio interfer-
ence suppression filter is required for DC1-...Nx-... models.
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com
1 DC1 device series
1.4 Rated operational data
1)
17

Advertisement

Table of Contents
loading