h Motor connection with output voltage U
The connection in the motor feeder is implemented with a screened cable that is earthed on both sides
across a large area (PES).
Rated operational current (I
DC1-1D...: 2.3 - 5.8 A
DC1-12...: 2.3 - 15 A
DC1-32...: 2.3 - 18 A
DC1-34...: 2.2 - 24 A
100% at an ambient temperature of +50 °C with an overload capability of 150% for 60 s
and a starting current of 175% for 2 s.
i Three-phase asynchronous motor
Continuously variable speed control for motors with the rated motor shaft outputs (P
DC1-1D...: 0.37 - 1.1 kW (230 V, 50 Hz) or 0.5 - 1.5 HP (230 V, 60 Hz)
DC1-12...: 0.37 - 4 kW (230 V, 50 Hz) or 0.5 - 5 HP (230 V, 60 Hz)
DC1-32...: 0.37 - 4 kW (230 V, 50 Hz) or 0.5 - 5 HP (230 V, 60 Hz)
DC1-34...: 0.75 - 11 kW (400 V, 50 Hz) or 1 - 15 HP (460 V, 60 Hz)
j Control section with operating unit and control buttons, seven-segment display, control voltage,
plug-in control signal terminals
k RJ45 interface for the computer and fieldbus connection (OP bus, Modbus RTU, CANopen)
DC1 variable frequency drive 12/13 MN04020003Z-EN www.eaton.com
(0 to 100% U
) and output frequency f
2
e
, output current):
e
1 DC1 device series
1.7 Features
(0 to 500 Hz)
2
):
2
21