Table 18 on page 45 shows the three canister status LEDs on each of the node
canisters. Figure 5 on page 45 shows the LEDs on the node canister.
44
Storwize V7000 Unified: Problem Determination Guide Version
Table 17. Power-supply unit LEDs (continued)
Power
supply
Fan
ac failure
OK
failure
Off
On
Off
On
Off
Off
Off
Off
On
Off
On
On
Flashing
X
X
Off
Flashing
Flashing
dc failure
Status
On
No ac power to
this power
supply
Off
Power supply is
on and
operational.
Off
Fan failure
On
Communication
failure and
power supply
problem
X
No canister is
operational.
Flashing
Firmware is
downloading.
Action
1. Check that the switch
on the power supply
unit is on.
2. Check that the ac
power is on.
3. Reseat and replace
the power cable.
No actions
Replace the power
supply unit.
Replace the power
supply unit. If replacing
the power supply unit
does not fix the problem,
replace the enclosure
chassis.
Both canisters are either
off or not seated
correctly. Turn off the
switch on both power
supply units and then
turn on both switches. If
this action does not
resolve the problem,
remove both canisters
slightly and then push
the canisters back in.
No actions. Do not
remove ac power.
Note: In this case, if
there is a battery in a
power supply unit, its
LEDs also flash.