Table 23. SMART ASC/ASCQ error codes and messages (continued)
ASC
ASCQ
Description
11
02
ERROR TOO LONG TO CORRECT
11
03
MULTIPLE READ ERRORS
11
04
UNRECOVERED READ ERROR - AUTO REALLOCATE FAILED
11
0A
MISCORRECTED ERROR
11
0B
UNRECOVERED READ ERROR - RECOMMEND REASSIGNMENT
11
0C
UNRECOVERED READ ERROR - RECOMMEND REWRITE THE
DATA
11
0D
DE-COMPRESSION CRC ERROR
11
0E
CANNOT DECOMPRESS USING DECLARED ALGORITHM
11
12
AUXILIARY MEMORY READ ERROR
11
13
READ ERROR - FAILED RETRANSMISSION REQUEST
11
14
READ ERROR - LBA MARKED BAD BY APPLICATION CLIENT
12
00
ADDRESS MARK NOT FOUND FOR ID FIELD
13
00
ADDRESS MARK NOT FOUND FOR DATA FIELD
14
00
RECORDED ENTITY NOT FOUND
14
01
RECORD NOT FOUND
14
05
RECORD NOT FOUND - RECOMMEND REASSIGNMENT
14
06
RECORD NOT FOUND - DATA AUTO-REALLOCATED
15
00
RANDOM POSITIONING ERROR
15
01
MECHANICAL POSITIONING ERROR
15
02
POSITIONING ERROR DETECTED BY READ OF MEDIUM
16
00
DATA SYNCHRONIZATION MARK ERROR
16
01
DATA SYNC ERROR - DATA REWRITTEN
16
02
DATA SYNC ERROR - RECOMMEND REWRITE
16
03
DATA SYNC ERROR - DATA AUTO-REALLOCATED
16
04
DATA SYNC ERROR - RECOMMEND REASSIGNMENT
17
00
RECOVERED DATA WITH NO ERROR CORRECTION APPLIED
17
01
RECOVERED DATA WITH RETRIES
17
02
RECOVERED DATA WITH POSITIVE HEAD OFFSET
17
03
RECOVERED DATA WITH NEGATIVE HEAD OFFSET
17
05
RECOVERED DATA USING PREVIOUS SECTOR ID
17
06
RECOVERED DATA WITHOUT ECC - DATA AUTO-REALLOCATED
17
07
RECOVERED DATA WITHOUT ECC - RECOMMEND
REASSIGNMENT
17
08
RECOVERED DATA WITHOUT ECC - RECOMMEND REWRITE
17
09
RECOVERED DATA WITHOUT ECC - DATA REWRITTEN
18
00
RECOVERED DATA WITH ERROR CORRECTION APPLIED
18
01
RECOVERED DATA WITH ERROR CORR. & RETRIES APPLIED
18
02
RECOVERED DATA - DATA AUTO-REALLOCATED
18
05
RECOVERED DATA - RECOMMEND REASSIGNMENT
67