Series 200
240 to 243
Num.
Compo-
nent
240
S10
241
S12
242
S10
243
S12
Line
Units
VCCM
All
VCCWE
Conditions
Cover not detected in the up
position Only on models 112!
During the rise of basket
(AutoLift) phase, no change of
status to limit switch
Cover does not leave the up
position. Only on models 112!
During the descent of basket
(AutoLift) phase, no change of
status to limit switch
Serial number (starting from)
ExxXH1009xxxxxxx
Diagnosis
● Check supply 17-24 VDC of T2 on the A5 board
● Check supply 11.5 VAC of T1 on the Main Board A2
● Check operation of motor M3 or M7. If the motor oper-
ated suspect the internal limit switches.
● Check the activation of the limit switches by the tilting
mechanism.
● Check proper feedback from the limit switches to the
board via the diagnostic mode.
● Check supply 17-24 VDC of T2 on the A5 board
● Check supply 11.5 VAC of T1 on the Main Board A2
● Check operation of motor M3 or M7. If the motor oper-
ated suspect the internal limit switches.
Sw
01-00-08
XIII.07
Service message module
Revision
v03 • July-2016 • Hen