VarioCooking Center WHITEFICIENCY Series Original Technical Instructions page 149

Table of Contents

Advertisement

VCC 112, index H
AutoLift
(lid tilting), actuators M3 - M7
TM
1
Detection of the Autolift
pressure.
Non-pressure units
2
Pressure units
3
Line
Units
VCCM
112
VCCWE
position, difference between units with or without
TM
Serial number (starting from)
E11xH1009xxxxxxx
Up position of the lid:
●Actuator stop on internal microswitch
●Detection via limit switch (S10 or S12)
Down position of the Autolift
●Determined by stop on internal limit switch, no
feedback to the electronics!
Never completely lower the lid when
it is in AutoLift low position.
Down position of the lid:
●Pressure unit (ExxP...) only to allow the lid to be
locked.
●Detection via limit switch S11 or S13
Attention!
●Do not confuse the limit switches S10/S12 with
S11/S13!
●S11 and S13 are only fitted to the pressure
devices, and are used to detect the closed
position of the lid to allow it to be locked.
Sw
X.21
Motorisation Module
Fig. 2
:
TM
Fig.3
Revision
v03 • July-2016 • Hen