VarioCooking Center WHITEFICIENCY Series Original Technical Instructions page 198

Table of Contents

Advertisement

100 series
100 to 128
Num.
Compo-
nent
B12.1 to
100
B12.6
B13.1 to
101
B13.6
110
B1
111
B2
120
PCB A2
121
B4
122
B5
123
B6
124
B7
125
B8
126
B9
127
B10
128
B11
129
B14
130
B15
131
B16
132
B17
Line
Units
VCCM
All
VCCWE
Conditions
Temperature measured >
300°C
Temperature measured >
300°C
Temperature measured >
655°C = Err.
Temperature measured >
655°C = Err.
Temperature measured >
80°C
Temperature measured >
655°C = Err.
Serial number (starting from)
ExxXH1009xxxxxxx
Diagnosis
● Check the connection of the thermocouple to the board
● Exchange the thermocouple if necessary
● If necessary exchange the corresponding board
If the temperature measured is -30°C (-22°F) this
indicates that the device needs allocation
● After a thermocouple or a board is exchanged it may
be necessary to carry out another allocation, or a
calibration of the unit.
Sw
01-00-08
XIII.04
Service message module
Revision
v03 • July-2016 • Hen