Heating system: general
Protection against overheating
Characteristic of "Thick Film" heaters
The leakage current generated by the heating element is proportional to the temperature. Therefore
is important to avoid overheating in order not to cause any damage.
Leakage current v. Temperature of the heating element:
1
I [mA]
Units fitted with a differential switch
(2011/10 to 2013/05)
In these units it is the differential switch that acts
as protection against overheating. If leakage
current generated reaches the limit of the
differential switch, it cuts the power supply.
Untimely
disconnection
switch is not necessarily related to overheating.
The
maximum
service mode should be checked first in the
Measurements chapter in real time.
The fact that our units are fitted with a
differential switch does exempt you from installing
differential protection in the electrical cabinet
according to the standards in force in your country.
See also the chapter 'power supply, safety chain'.
Line
Units
VCCM
All
VCCWE
Heater temperature
of
the
differential
temperatures
recorded
Serial number (starting from)
ExxXH1009xxxxxxx
T [°C]
Units not fitted with a differential switch
(from 2013/05)
The use of new-generation heating element has
allowed differential switches to be done away
with. In this case protection is ensured by a bi-
metal (klixon). Each heating zone is fitted with
these, and they are connected in series in the
safety chain. In case of overheating the bimetal
shuts off the unit via the main contactor K1.
in
Sw
IX.07
Heating system module
Revision
v03 • July-2016 • Hen