VarioCooking Center WHITEFICIENCY Series Original Technical Instructions page 117

Table of Contents

Advertisement

Allocation
Practical guide
Access to the allocation (service mode)
Password for access to the mode: TECLEVEL
Case sensitive!
Points to note
The pan must be cold, empty and clean.
Procedure
Start the allocation of the thermocouples by
pressing the corresponding button.
After allocation a calibration should be carried out.
The automatic process lasts between 5
and 10 minutes depending on the model (112,
211 or 311). It is interrupted when an anomaly
occurs with the corresponding error code being
displayed. (See following pages)
Heating sequence:
112 / 112T
Line
Units
VCCM
All
VCCWE
112L
Serial number (starting from)
ExxXH1009xxxxxxx
TECLEVEL
Description of the automatic sequence:
I. Heat up a zone.
II. Wait.
III. Search for a thermocouple with its temperature
rising and allocation of the thermocouple/
connector on the A4 board in the heating zone.
IV. Back to step I, next heating zone.
211
Sw
IX.11
Heating system module
Allocation
311
Revision
v03 • July-2016 • Hen