Allocation
Error codes
Troubleshooting errors during the allocation process
Error code
Explanation
Error-20
Problem with reading, the tem-
perature values read are too
inconsistent or have too large
variations.
Error-17
Time
thermocouple
Despite heating no rise in
temperature
during the set period of time.
Error-15
Thermocouple already assigned ●Two heating zones are definitely active at the
Error-14
Process complete but non-viable ●Certain temperature measurements are
Error-13
Measured temperatures greater
than 150°C
Error-12
2 thermocouples detect the
same heating zone
Line
Units
VCCM
All
VCCWE
limit
is
reached,
not
detected.
was
detected
Serial number (starting from)
ExxXH1009xxxxxxx
Troubleshooting
●Poor contact from the thermocouple to the board
●Defective thermocouple
●Defective A4 board
●Electrical power > Missing phase? Before /
After the main contactor?
●SSR fault? Command from the board?
●Fault with a thermocouple or the corresponding
board
●Energy optimisation system (Sicotronic)
●Fault with a heater, faulty wiring
same time, check the wiring
suspect, the allocation may not be reliable
●Check the wiring
●Starting temperature is too high, repeat the
test, cooling the pan first. T° < 50°C preferably
●SSR short circuited
●Defective thermocouple
●Wiring fault, check the SSR wiring, and heater
wiring if appropriate
Sw
IX.13
Heating system module
Revision
v03 • July-2016 • Hen