VarioCooking Center WHITEFICIENCY Series Original Technical Instructions page 126

Table of Contents

Advertisement

Calibration
Calibration log
Troubleshooting errors during the allocation process
Error code
Explanation
Error-40
The read temperature values
are too high. Same conditions
as for displaying service mes-
sages.
Error-38
Time limit reached without rec-
ognition of boiling.
(T° core probe < 80°C
or core probe temperature vari-
ation > 0.1 ° C)
Error-36
At least one thermocouple
temperature
> 200°C
Error-33
Heating zone calibration result
outside tolerances [200; 6000]
Error-32
At least one point of the left
core probe is outside given
tolerance [-3°C; +3°C]
Line
Units
VCCM
All
VCCWE
measured
Serial number (starting from)
ExxXH1009xxxxxxx
Troubleshooting
●Bad contact from thermocouple to PCB
●Broken thermocouple
●PCB board malfunction
●Electrical power > Missing phase? SSR fault?
SSR command? SSR malfunction?
●Fault with a thermocouple or the correspond-
ing board
●Energy
optimisation
(Sicotronic)
●Fault with one or more heater(s), bad wiring?
●Core probe fully submerged?
●Water present?
●Broken thermocouple
●PCB board malfunction
●SSR malfunction
●Check
which
Service mode > diagnosis > Real time data
●Check the thermocouple for good contact
with pan bottom
●Check the centring of the thermocouple
●Thermocouple or corresponding PCB mal-
function
●For
pressure
Check for correct function of the pressure
sensor? Pressure circuit blocked?
●Enough water present?
●Core probe fully submerged?
●Altitude setting?
●For
pressure
Check for correct function of the pressure
sensor? Pressure circuit blocked?
●Thermocouple or corresponding PCB mal-
function
Sw
IX.20
Heating system module
system
active
thermocouple:
units
only:
units
only:
Revision
v03 • July-2016 • Hen