VarioCooking Center WHITEFICIENCY Series Original Technical Instructions page 200

Table of Contents

Advertisement

Series 200
220 to 231
Num.
Compo-
nent
220
S6
221
S18
S7
222
+ (S21 >
211/311)
223
S19
230
S8
231
S20
Line
Units
VCCM
All
VCCWE
Conditions
Cover not unlocked
During unlocking limit switch
no change of status
Cover not locked
During locking limit switch no
change of status
No signal from the pan valve
motor micro switch
Serial number (starting from)
ExxXH1009xxxxxxx
Diagnosis
● Check supply 17-24 VDC of T2 on the A5 board
● Check supply 11.5 VAC of T1 on the Main Board A2
● Check motor M4 or M8. If the motor operated suspect the
internal limit switches.
● If the motor does not work despite the presence of all
the power to the boards A2, A5 check pressure switch
F11 or F13
● Check supply 17-24 VDC of T2 on the A5 board
● Check supply 11.5 VAC of T1 on the Main Board A2
● Check motor M4 or M8. If the motor operated suspect the
internal limit switches.
● Check supply to motor M5 or M9
● Check operation of motor M5 or M9. If the motor is
operating suspect the microswitch.
Sw
01-00-08
XIII.06
Service message module
Revision
v03 • July-2016 • Hen