VCC 211/311
Torque limiter, Index H units
Pressure units 211/311 until August 2011
These devices are fitted with a torque limiter mounted in series in the supply to the unlocking motor.
If the power supply is greater than 2A to the unlocking motor M4 the torque limiter stops the power
to the actuator.
Components
1
T2
17-24VDC
Wiring
Line
Units
VCCM
211P, 311P
VCCWE
A5 (X-Relay)
2
Serial number (starting from)
E21xH1009xxxxxxx, E31xH1009xxxxxxx
F12
20 mbar
M4
Motorisation Module
F14
Sw
Revision
v03 • July-2016 • Hen
X.34
M4