Battery Electrolyte Level - Check - Mahindra Genio DC BS-IV Maintenance Manual

Hide thumbs Also See for Genio DC BS-IV:
Table of Contents

Advertisement

Maintenance Manual
GENIO DC
(BS-III & BS-IV)
705-MAT-0031 : 0.10 hrs

BATTERY ELECTROLYTE LEVEL - CHECK

Refer above illustration –
1. Ensure the electrolyte level between MIN and MAX marks (if the electrolyte level is
less than the MIN mark, then top up the electrolyte to the recommended level with
distilled water.
2. Check the terminals clamps for clean and tightness; if required clean it and fix it tightly.
3. Check the other end of battery cables for tightness.
Battery Electrolyte Level Check to be inspected at 5000kms, 10000kms,
15000kms, 20000kms and then every 10000kms.
The repair methods given by the manufacturer in this document are based on the technical specifications, current at the time of release. The methods may be modified as a result of changes
introduced by the manufacturer in the production of the various component units and accessories from which the vehicles are manufactured. The reproduction, translation, transmission, in part of or
whole of the present document, are prohibited without the prior written consent of Mahindra & Mahindra Ltd. The use of this document by any person other than the trained personnel, at the
Authorized Service Centre of Mahindra & Mahindra Ltd., will amount to unauthorized use and shall be liable for penalty/prosecution © 2011 Mahindra & Mahindra Ltd.
Battery Electrolyte
Level - Check
NOTE –
Battery rating: 12V, 65Ah.
Toping up should be done with distilled
water only.
Never use normal water or mineral water to
top battery electrolyte.
Vent holes should be clear.
Clean the terminals.
Use petroleum jelly in case of terminals gets
rusty.
Tighten the terminals along with cable
fitments properly.