6.5.8 Setting 0 V ... 10 V
V
5.125
5.0
0
0
0
Start value
At this setting, the start value of the measurement range is converted to 0 V and the end value to 10 V.
Intermediate values are converted proportionately.
Values below the start value cannot be evaluated (output 0 V). If the value exceeds the end value, the
output voltage increases linearly to a maximum of 10.25 V (approx. 102.5 % of the measurement
range). Further increases cannot be evaluated (output 10.25 V).
46
100
102.5
% Meas.
End value
range