Pepperl+Fuchs HID2891 Manual page 42

Frequency converter
Table of Contents

Advertisement

Frequency Converter HiD2891
6.4.2 Setting 4 mA ... 20 mA (NE 43)
mA
20.5
20.0
4.0
3.8
0
-1.25
At this setting, the start value of the measurement range is converted to 4 mA and the end value to
20 mA. Intermediate values are converted proportionately.
If the value falls below the start value, the output current decreases linearly to a minimum of 3.8 mA
(-1.25 % of the measurement range). Further decreases cannot be evaluated (output 3.8 mA). If the
value exceeds the end value, the output current increases linearly to a maximum of 20.5 mA (approx.
103 % of the measurement range). Further increases cannot be evaluated (output 20.5 mA).
6.4.3 Setting 4 mA ... 20 mA limited
mA
20.0
4.0
0
At this setting, the start value of the measurement range is converted to 4 mA and the end value to
20 mA. Intermediate values are converted proportionately.
Values below the start value cannot be evaluated (output 4 mA). Values above the end value cannot
be evaluated either (output 20 mA).
40
0
Start value
0
Start value
≈ 103
100
% Meas.
End value
range
100
% Meas.
End value
range