Installation

Attach Clamp Mounting Rails

For installation convenience, four hanging points are provided on the enclosure, two each in
planes 90 degrees from each other.
A
Item#
Name
1
Clamp Mounting Rails 2510A2017
CAUTION:
experience, including amongst others, calculating the working load limit
(WLL) of the truss system, a specialized knowledge of the installation material
being used, and a periodic safety inspection of all installation materials and
the luminaire. Improper installation can result in bodily injury. This luminaire
must be installed by qualified personnel only.
ATTENTION :
nécessite une vaste expérience, qui inclut notamment le calcul de la charge
nominale du système de pont, une connaissance spécialisée du matériel utilisé
pour l'installation et l'inspection régulière de tout l'équipement de
l'installation et du luminaire. Une installation incorrecte peut entraîner des
blessures corporelles. Ce luminaire doit uniquement être installé par du
personnel qualifié.
1.
Install the truss clamps (not provided) to the clamp mounting rails.
Installation
1
Part Number Notes
Risk of Personal Injury! Overhead mounting requires extensive
Risque de Blessures Corporelles ! L'installation en hauteur
Two clamp mounting rails are provided with the Relevé Spot luminaire for
attachment to truss clamps (not provided) or other compatible hardware for
installation.
The clamp mounting rails feature a safe-latching system for secure fit to the
hanging points on the enclosure.
B
Securely install on the provided attach-
ment points on the base of the enclosure.
10 in
25.4 cm
5 in
12.7 cm
21