Before You Begin Installation

Review the following information before installing the F-Drive R12.

Installation Requirements

Ambient operating temperature 0–40°C (32–104°F), 5–95% non-condensing humidity.
Dry locations only.
The R12 requires a 19-inch equipment rack that must support the weight of an R12 frame,
twelve output cards, and any power supplies and accessories.
The R12 is a 48 VDC input product that requires an external power supply for operation.
Clearance Requirements
F-Drive R12 Driver
CAUTION:
cabinet wall.
ATTENTION :
pouces au mur de l'armoir.
MEAN WELL Power Supply Frame
If you are installing a MEAN WELL RKP-1UI three-bay external power supply frame, the built-in
DC fans require 10 cm (3/8 in) clearance around the ventilation holes after mounting the three-
bay frame in the 19-inch equipment rack.
WARNING:
behind the installed MEAN WELL three-bay frame. Equipment mounted
above or below a MEAN WELL three-bay frame must be 35 cm (14 in) or less
in depth. Equipment with a depth of more than 35 cm (14 in) mounted
immediately above or below a MEAN WELL three-bay frame may cause an
unsafe electrical connection due to mechanical interference with the power
bussing connections.
AVERTISSEMENT :
de 20 mm (3/4 po) derrière le châssis du rack MEAN WELL installé. Tout
équipement monté au-dessus ou au-dessous d'un rack MEAN WELL doit
avoir une profondeur de 35 cm (14 po) ou moins. Tout équipement d'une
profondeur de plus de 35 cm (14 po) monté immédiatement au-dessus ou
au-dessous d'un rack MEAN WELL peut provoquer une connexion électrique
dangereuse en raison d'interférences mécaniques avec les connexions de bus
d'alimentation.
Note:
installed vertically adjacent in the equipment rack.
Chapter 1 
To reduce risk of fire, do not install closer than 3 inches to
Pour reduire les risques d'incendie, n'installez pas plus de 3
RISK OF ELECTRIC SHOCK! Maintain 20 mm (3/4 in) clearance
RISQUE DE CHOC ÉLECTRIQUE! Conservez un espace
If you are bussing two or more RKP-1UI rack systems together, they must be
9