6.0 COMPONENT REPLACEMENT (Cont.)
6.9.2 Agitator Motor (Cont.)
1) Shut off power to the dispenser and unplug the
power cord from the wall receptacle.
2) Remove the enclosure top panel and then the
left-side and rear access panels.
3) Remove the air compressor from the left side of
the enclosure (refer to section 6.5).
4) Unplug the agitator-motor wiring plug from the
ice bank controller module socket (Fig. 6-14).
NOTE: You can obtain access to the controller
wiring sockets by removing the splash shield
and the Main PCB housing refer to section 6.3).
Figure 6-14 - Agitator Wiring Socket on Controller Module
5) Loosen the thumbscrew at the base of the agi-
tator motor (Fig. 6-13).
6) Lift and angle the motor assembly to withdraw
it from the ice bank.
7) Install the replacement motor in reverse order.
Publication Number: 548000106SER
Figure 6-15 - Agitator Pump Hose Orientations

6.9.3 Ice Bank Controller

1) Shut off power to the dispenser and unplug the
power cord from the wall receptacle.
2) Remove the enclosure top panel and then the
left-side access panel.
3) Remove the drip tray, splash panel and the
Main PCB housing (refer to section 6.3).
4) Unplug the four wiring connectors from the ice
bank controller module (Fig. 6-16).
Figure 6-16 - Ice Bank Controller Module Removal