D25 - electrolyte density at 25 ° C
Dt - measured density of electrolyte at t °C
T—— electrolyte temperature when measuring density
9.4.6 Storage, transportation and installation of the accumulator
The forklift must be parked on the level ground steadily. To prevent short
circuit, naked cable ends and the terminal posts should be covered with
insulated covers. When pulling out the accumulator, properly arrange removed
accumulator's connectors and cables without blocking access of the accumulator.
When install or remove the accumulator with a crane, make sure the load
capacity is sufficient (weight of the accumulator is marked on both the
nameplates of the accumulator and the forklift.) The crane must pull vertically to
prevent the battery box from being damaged. The hooks of the crane should be
safe and secure. Never let the hooks fall on an individual battery .
— Press emergency stop switch and turn the power supply switch to OFF
position
— Remove the connectors of accumulator cables.
—Connect the lifting device to lifting holes.
—Lift out the accumulator from the top and move away with handling
equipment.
Perform installation in reverse order of above steps. It is noticeable to put
the accumulator in right position and connect the cables securely. After
reinstalling the accumulator, always check all cable connections and connectors