24 Appendix
24.1
Terms, abbreviations, formula symbols

24.1.1 Terms

Term
Meaning
Installation side
Density and specific heat capaicity are functions of temperature. It is therefore of sig-
nificance for the calculation which temperature measuring value is used. The installa-
tion side (hot or cold side) determines this.
Paired temperature
Two temperature sensors are selected during production in such a way that the meas-
sensors
uring errors in the temperature difference measurement are below the stipulated limiting
values.
Combined cool-
Energy meter which, in the heating operation (T supply > T return) or in the cooling op-
ing/heating meter
eration (T return > T supply) cumulates the energy in separate meters. See also 'BDE'.
Combined heat
Heat meter comprising separate components: flow sensor, pair of temperature sensors
meter
and calculator. The components can be separately replaced, altered and recalibrated.
Conformity as-
Legally binding declaration of metrological EC conformity
sessment
Corresponds to devices with domestic pattern/type approval of the initial calibration
Current value
Momentary value of, e.g. temperature, flow rate
Supply / return flow
Part of a hydraulic circuit in which the medium flows into/out of a heat exchanger. In
heating or cooling circuits, the flow sensor should always be installed in the return pipe,
since effects resulting from temperature and condensation are less there, both in heat-
ing and cooling systems.
Meter reading
Energy, volume or mass, resulting from totalising a current value.
As a rule, a meter reading does not get smaller

24.1.2 Abbreviations

Abbreviation
Meaning
BDE
Bi-directional energy measurement: If Ts > Tr , then meter E is incremented
If Tr > Ts , then meter E- is incremented
BDV
Bi-directional volume measurement, energy calculation for reverse flow:
for forward flow, meter E is incremented, for reverse flow, meter E-
®
CALEC
EM
CALEC
fm
Flow sensor, measures the flow and supplies a flow signal
Limit
Limiting value
IR
Infrared
IrDA
Infrared interface according to the Standard of the Infrared Data Association (IrDA)
Class IA...IE
Classification of pulse inputs according to EN 1434
Class OA...OE
Classification of pulse transmitters according to EN 1434
SC det
Short-circuit/interrupt detection; when activated, short-circuiting and power cuts are de-
tected and displayed as errors
Mod
Device version without protective housing ("Mod"ule)
Prot
Device version with protective housing ("Prot"ected)
Platinum resistance temperature sensors according to DIN IEC 60751,
Pt100
R = 100 Ohm at 0°C
PFM
Pulse-frequency modulation or pulse/frequency modulated signal
A measured value is transmitted as frequency from 0 – 10 kHz
RDA
Remote Display Adapter, 2 adapters for operation of the detached display module
calc 1 ... 3
Calculator 1 to 3
®
CALEC
energy master installation and operating instructions
®
energy master
66