Nmi Led Is Lit - Avaya Aura S8800 Maintaining

Server for sip enablement services
Hide thumbs Also See for Aura S8800:
Table of Contents

Advertisement

Troubleshooting
• If the server booted, the failing DIMM is disabled, and the DIMM LED is lit:
a. If the LEDs are lit by two DIMMs and you have a monitor, check the system event
b. If the LED is lit by only one DIMM, replace that DIMM.
Related topics:
Sequence for populating DIMM connectors
Sequence for populating DIMM connectors
Removing a memory module
Removing a memory module
Installing a memory module
Installing a memory module
System board LEDs
System board LEDs

NMI LED is lit

The NMI LED on the light path diagnostics panel is lit when a nonmaskable interrupt occurs,
or the NMI button is pressed.
Troubleshooting steps
Procedure
1. If you have a monitor, check the system event log for information about the error.
2. Shut down server and remove the power cord.
3. Check that all plug-in cards and devices are firmly installed.
4. Turn on the server.
5. If the server does not boot, replace server.
66
Maintaining the Avaya S8800 Server for Avaya Aura
- If the DIMM LED that corresponds to the new DIMM socket is lit, replace the
DIMM.
- If the DIMM LED that corresponds to the original DIMM socket is lit, replace
server.
log for a PFA event for one of the DIMMs, and then replace that DIMM. Otherwise,
replace both DIMMs
on page 20
on page 20
on page 22
on page 22
on page 49
on page 49
Comments? infodev@avaya.com
on page 17
on page 17
®
SIP Enablement Services
November 2009