2. Commissioning
Module no.
Module
0
Field bus node CPX−FB32
1
Digital 8−input module CPX−8DE
2
Digital 4−output module CPX−4DA
3
MPA1 pneumatic module (8 DO)
4
MPA1 pneumatic module (8 DO)
5
MPA2 pneumatic module (4 DO)
6
MPA2 pneumatic module (4 DO)
*)
8 bits occupied, 4 bits used
Tab. 2/7:
Addressing the example terminal 1 (see Fig. 2/1)
Festo P.BE−CPX−FB32−EN en 0605NH
The following table shows the address assignment for the
CPX terminal in Fig. 2/1:
If modular EDS is used, the addresses will be assigned in
bytes. In the example above, the output addresses therefore
change as from modules 2, 5 and 6.
Input address
I0 ... I7
Output address
*)
O0 ... O7
O8 ... O15
O16 ... O23
*)
O24 ... O31
*)
O32 ... O39
2−11