Huawei TaiShan 200 Series User Manual page 85

Table of Contents

Advertisement

TaiShan 200 Server
User Guide (Model 2280)
Issue 04 (2020-01-16)
Figure 5-36 Querying alarm information (earlier than iBMC V500)
If the iBMC version is V500 or later, view Alarm Statistics on the
Home page, as shown in
Figure 5-37 Querying alarm information (iBMC V500 or later)
d.
Clear any alarms if present. For details, see the
iBMC Alarm Handling
Check the server using the iBMC CLI.
a.
Set an IP address for the PC. This IP address must be on the same
network segment as the iBMC management network port.
b.
Connect a network cable from the PC to the iBMC management network
port of the server.
c.
Start a Secure Shell (SSH, PuTTY), tool on the PC and log in with the IP
address of the iBMC management network port and iBMC user name and
password.
By default, SSH is used to log in to the iBMC. If the SSH service is disabled,
enable it by choosing Configuration > Services on the iBMC WebUI.
d.
Run the ipmcget -d ver command to view the server version information.
Check that the server versions meet site requirements.
iBMC:/->ipmcget -d ver
------------------- iBMC INFO -------------------
IPMC CPU: Hi1710
IPMI Version: 2.0
CPLD Version: (U6076)1.00
Active iBMC Version: (U68)3.32
Active iBMC Build: 003
Active iBMC Built: 14:32:33 Apr 15 2019
Backup iBMC Version: 3.32
SDK Version: 3.26
SDK Built: 10:53:30 Mar 18 2019
Active Uboot Version: 2.1.13 (Dec 24 2018 - 20:23:20)
Backup Uboot Version: 2.1.13 (Dec 24 2018 - 20:23:20)
----------------- Product INFO -----------------
Product ID: 0x0001
Product Name: TaiShan 200 (Model 5280)
Copyright © Huawei Technologies Co., Ltd.
Figure
5-37.
.
5 Install and Configure
TaiShan Rack Server
78

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taishan 2280

Table of Contents