Figure 5-24 Securing a power cable
Step 4 Insert the other end of the power cable into the AC power socket on the cabinet.
The AC power socket is located horizontally at the rear of the cabinet. Select a
jack on the power socket for connection.
Step 5 Bind the power cable to the CMA using cable ties.
----End

5.8.7.2 Connecting DC PSU Cables

● Use dedicated power cables to ensure equipment and personal safety.
● Use power cables only for dedicated servers. Do not use them for other devices.
● Connect the power cables of the active and standby PSUs to different power
● Ground the equipment before powering it on.
Procedure
Step 1 Wear an ESD wrist strap. For details, see
Step 2 Take the spare part out of its ESD bag.
Step 3 Connect the power cables to the PSUs.
1.
Issue 04 (2020-01-16)
NO TICE
distribution units (PDUs) to ensure reliable system operation.
Put the OT terminal (for the ground cable) on the screw removed from the
ground hole, install the screw on the ground hole, and tighten the screw. See
(1) in
Figure
5-25.