Ipmi_Flsupd - Motorola PPC/CPCI-690 Reference Manual

Table of Contents

Advertisement

Command Set

ipmi_flsupd

Danger
D
ESCRIPTION
S
YNTAX
P
ARAMETERS
E
XAMPLE
4 - 40
Defect IPMI Flash
When updating the IPMI flash with wrong data, it becomes unusable.
Only update the IPMI flash with data provided by Motorola.
Command to start an IPMI flash update. An update via IPMB is possible
with the address option. For a detailed description of the update procedure
refer to the current version of IPMI Firmware for PPC/CPCI-690 and PPC/CP-
CI-695 Installation Guide available via S.M.A.R.T.
IPMI_FLSUPD <begin> <end> [<addr>]
Parameter
Description
begin
Start of the S-record
end
End of the S-record
addr
IPMB I2C address of the connected board.
PowerBoot
netload ipmicore_all_0_96.s3r 100000 192.168.41.111
192.168.41.1
PHY-Device at 100MB/s and full duplex negotiated
WANCOM MAC ADDRESS : 00:80:42:11:E7:3C
Transmitting ARP-REQUEST... Reception of ARP-REPLY
Transmitting TFTP-REQUEST to server 00:80:42:10:5B:C7, IP
192.168.41.1
PACKET:871 - loaded $00100000..$0016CD13 (445716 bytes)
PowerBoot> ipmi_flsupd 100000 162b3b
0 |######################################| 100%
Firmware update finished waiting for IPMI reset
Firmware update successful
PowerBoot>