Motorola PPC/CPCI-690 Reference Manual page 90

Table of Contents

Advertisement

Command Set
P
ARAMETERS
begin
end
e
c
E
XAMPLE
4 - 16
Specifies the first byte of the memory area to be tested
Specifies the first area of the memory area not to be tested
Achieves that the test runs endlessly
Achieves that the test uses the cache
PowerBoot> bt 100000 200000
Blocktest at single mode, testing 65536 bytes from 0x10000..0x1FFFF
Checkerboard test 8bit......done
Checkerboard test reverse...done
Walking ones test 8bit......done
Walking ones test reverse...done
Walking zeros test 8bit.....done
Walking zeros test reverse..done
Increment test 8bit.........done
Checkerboard test 16bit.....done
Checkerboard test reverse...done
Walking ones test 16bit.....done
Walking ones test reverse...done
Walking zeros test 16bit....done
Walking zeros test reverse..done
Increment test 16bit........done
Checkerboard test 32bit.....done
Checkerboard test reverse...done
Walking ones test 32bit.....done
Walking ones test reverse...done
Walking zeros test 32bit....done
Walking zeros test reverse..done
Increment test 32bit........done
Prime test 32bit............done
Prime test 32bit R/T........done
March-b test ...............done
--- Blocktest runs 1 times - 00000000 errors ---
PowerBoot>_