WARNING: if the belt is not tightened properly, during the
search for the positions it may slip between the belt and the
pinion. If this happens, stop the learning procedure by pressing
key P3 and stretch the belt by tightening the nut [D]. Then repeat
the recognition procedure starting from step 1.
74
3.5.3 – Testing the radio transmitter
To test the transmitter just press one of its 4 keys, make sure that the red
LED [A] ashes and that the automation carries out the related command.
The command associated to each button depends on how it has been
memorised (see paragraph 5.4 "Memorisation of radio transmitters").
75
T1
T3
3.6 – ADJUSTMENTS
3.6.1 – Selecting door speed
The door can be opened and closed at two speeds: "slow" or "fast".
To switch from one speed to the other press the P2 button [A] momen-
tarily; the corresponding P2 LED [B] will light up or go off; if the LED is off
the speed is "slow", if the LED is on the speed is "fast".
76
B
3.6.2 – Selecting the type of operating cycle
The opening and closing of the door can take place according to differ-
ent operating cycles:
• single cycle (semiautomatic): the door opens with a command and stays
open until the next command is given, causing it to close.
• complete cycle (automatic closing): the door opens with a command
and then closes automatically after a short time (for the time, see para-
graph 5.1.1 "Adjusting the parameters with the radio transmitter").
To switch from one operating cycle to the other, press the P3 button [A]
momentarily; the corresponding LED P3 [B] will light up or go off; if the
LED is off the cycle is "single", if the LED is on the cycle is "complete".
77
D
3.7 – TESTING AND COMMISSIONING
These are the most important operations, designed to guarantee the
maximum safety and reliability of the automation system.
The testing procedure can also be used as a periodic check of the devic-
es that make up the automation.
The testing and commissioning operations must be performed
by qualified and experienced personnel
tests should be conducted based on the risks involved and verify
the compliance of the system with applicable regulations, legi-
slation and standards, in particular with all the provisions of EN
standards 12445 and 12453 which establish the test methods for
sectional and overhead door automation systems.
[A] Led
3.7.1 – Testing
1 Make sure that the provisions contained in chapter 1 "WAR-
T5
NINGS" have been carefully observed.
2 Using the radio transmitter, test the opening and closing of the door and
make sure that the door moves in the intended direction.
T2
The test should be carried out a number of times to make sure that the
T4
door moves smoothly, that there are no points of excessive friction and
that there are no defects in the assembly or adjustments.
[B]
3 Check the proper operation of all the safety devices, one by one (photo-
cells, sensitive edges, etc.). In particular, each time a device is activated,
the BUS LED on the control unit ashes for a longer time, confirming
that the control unit recognises the event.
4 To check the photocells (if provided), pass a 5 cm diameter, 30 cm long
cylinder on the optical axis, first near TX, then near RX and finally at the
mid-point between them and make sure that in all these cases the device
is triggered, switching from the active to the alarm status and vice-versa;
finally, that it causes the intended action in the control unit, for example:
that it causes the reversal of the movement during the closing manoeuvre.
8
A
5 The control of the correct obstacle detection is performed with the
700x300x200mm test parallelepiped with 3 black sides and 3 polished
white or mirrored sides, according to the EN 12445 standard.
6 Measure the impact force according to EN standards 12445 and 12453.
If "motor force" control is used to assist the system for the reduction of the
impact force, try to find the adjustment that gives the best results.
7 Ensure that the entire mechanism is correctly adjusted and that the
automation system inverts the manoeuvre when the door collides with a
50 mm high object on the oor.
8 Ensure that the automation prevents or blocks the opening manoeuvre
hen the door is loaded
door's lower edge.
A
B
ho must establish
ith a mass of 20 kg, fixed in the middle of the
hat
English – 15