3.3.7 – Electrical connections to the control unit
1 Unscrew screw [A] and push button [B], to open the lid.
2 Thread the cables through the slit [C].
3 Refer to figure 65 for the electrical extra lo
various devices to the control unit terminals.
• The terminals have the same colour coding as the corresponding devic-
es; for example, the grey terminal (SbS) of the control unit must be con-
nected to the grey terminal (SbS) of the accessory.
• For most connections you do not need to observe any polarity; only for
the shielded cable of the aerial incorporated in the FL200 ashing light
(optional accessory) it is necessary to connect the central core and the
shield as sho n in figure 65.
• If you are using the asher's aerial, remove the piece of ire (connected
to the green terminal at the factory) and connect the RG58-type shielded
braiding.
• The terminals [D] can be removed in order to facilitate the operations as
sho n in figure 66; make the connections and then reinsert them.
4 When the connections have been completed, secure the cables using
suitable clamps.
5 To close the cover, turn and push until a click is heard. Secure the screw
[A].
65
FL200
FLASH
66
62
voltage connection of the
64
PH200
TX
FLASH
BUS
STOP
D
A
C
RX
SbS
63
B
NC
NO
English – 13