3.4 – POWER SUPPLY CONNECTION
The connection of AVIO to the mains must be made by a qua-
lified electrician.
To carry out tests, insert the plug for AVIO in a power outlet; if necessary,
use an extension cord.
67
3.5 – INITIAL CHECKS
As soon as the control unit is energised, you should check the following:
1 Make sure that the LED [A] ashes regularly,
second.
68
2 If the system is equipped with the PH200 photocells, make sure that the
SAFE LED [B] sho n in figure 69 ashes (on both TX and RX). The type of
ashing is irrelevant, it depends on other factors; hat matters is that it is
not always off or always on.
69
4 If the above conditions are not satisfied, you should immediately s itch
off the power supply to the control unit and check the cable connec-
tions more carefully. For more useful information see also chapters 5.5
"Troubleshooting" and 5.6 "Diagnostics and Signals".
3.5.1 – Recognition of the connected devices
When you have completed the initial checks, the control unit must rec-
ognise the devices connected to it on the "BUS" and "STOP" terminals.
1 On the control unit, press the P2 button [C] and hold it down for at least
three seconds, then release the button (Figure 71).
14 – English
ith about one ash per
A
FLASH
BUS
STOP
SbS
Led SAFE
71
A
B
2 Wait a fe seconds for the control unit to finish recognising the devices.
3 When the recognition procedure is completed, the STOP LED [A] must
remain on, while the P2 LED [B] must go off. If the P2 LED ashes it
means that an error has occurred: see paragraph 5.5 "Troubleshooting".
The connected devices recognition stage can be repeated again at any
time, even after the installation (for example, if an additional photocell is
installed); just repeat the procedure starting from step 1.
3.5.2 – Recognition of the door's open and closed positions
After recognising the devices, the control unit must recognise the door's
open and closed positions. During this stage, the stroke of the door from
the closing stop to the opening stop is detected.
1 Make sure that the carriage is attached.
2 Press key P3 [A] on the control unit and hold it down for at least three
seconds, then release the key (Figure 72).
72
B
• Wait until the control unit has completed the recognition stage: closing,
opening and re-closing of the door.
• If any device is triggered during the recognition stage, or the P3 key is
pressed, the recognition stage will be immediately interrupted. In this case
it must be repeated from the beginning.
• During the recognition stage the courtesy light
ashing light.
3 If the P3 LED [B] ashes at the end of the learning stage, it means that
there is an error; see paragraph 5.5 "Troubleshooting".
4 Press the yellow button [C] in figure 73 to execute a complete opening
and closing manoeuvre. Then push it again to perform a complete closing
manoeuvre. During these two manoeuvres the control unit memorises the
force needed at each point along the stroke.
73
C
It is important that these t o first manoeuvres are not interrupted by any
commands.
If the manoeuvres are not completed, repeat the recognition procedure
starting from step 1.
The position recognition stage can be repeated at any time in the future
(for instance, if one of the mechanical stops is moved); just repeat starting
from step 1.