STEP 7
These are the most important operations, designed to guarantee
the maximum safety and reliability of the automation system.
The testing procedure can also be used as a periodic check of
the devices that make up the automation.
The testing and commissioning operations must be
performed by qualified and experienced personnel who
must establish what tests should be conducted based on
the risks involved and verify the compliance of the system
with applicable regulations, legislation and standards, in
particular with all the provisions of EN standards 12445
and 12453 which establish the test methods for sectional
and overhead door automation systems.
7.1 – TESTING
1 Make sure that the provisions contained in chapter 1
"WARNINGS" have been carefully observed.
2 Using the radio transmitter, test the opening and closing of the
door and make sure that the door moves in the intended direc-
tion.
The test should be carried out a number of times to make sure
that the door moves smoothly, that there are no points of exces-
sive friction and that there are no defects in the assembly or
adjustments.
3 Check the proper operation of all the safety devices, one by one
(photocells, sensitive edges, etc.).
4 To check the photocells (if provided), pass a 5 cm diameter,
30 cm long cylinder on the optical axis, first near TX, then near
RX and finally at the mid-point between them and make sure
that in all these cases the device is triggered, switching from the
active to the alarm status and vice-versa; finally, that it causes the
intended action in the control unit, for example: that it causes the
reversal of the movement during the closing manoeuvre.
18 – English
The yellow "set" LED
light is permanently
on
The yellow "set" LED
light is permanently
on
movement must be reprogrammed.
The yellow "set" LED
light is permanently
movement when a mechanical stress point is detected (this
on
corresponds to increased motor effort). Adjust OBSTACLE
and FORCE knobs (slightly turn them clockwise) to solve
The yellow "set" LED
this and check gate mechanics if necessary.
light is permanently
on
The yellow "set" LED
light turns off

TESTING AND COMMISSIONING

33
5 The control of the correct obstacle detection is performed with
the 700x300x200mm test parallelepiped with 3 black sides and
3 polished white or mirrored sides, according to the EN
standard.
6 Measure the impact force according to EN standards 12453. If
"motor force" control is used to assist the system for the reduc-
tion of the impact force, try to find the adjustment that gives the
best results.
7 Ensure that the entire mechanism is correctly adjusted and that
the automation system inverts the manoeuvre when the door col-
lides with a 50 mm high object on the floor.
8 Ensure that the automation prevents or blocks the opening
manoeuvre when the door is loaded with a mass of 20 kg, fixed in
the middle of the door's lower edge.
7.2 – COMMISSIONING
The commissioning operations can be performed only
after all the tests have been successfully carried out. Par-
tial commissioning or implementation of "temporary" con-
ditions are not permitted.
1 Prepare the technical documentation for the automation, which
must include at least: assembly drawing (e.g. figure 1), wiring dia-
gram (e.g. figure 65), analysis of hazards and solutions adopt-
ed, manufacturer's declaration of conformity of all the devices
installed. For AVIO use Annex 1 "CE Declaration of Conformity of
the AVIO components".
2 Post a label on the door providing at least the following data: type
of automation, name and address of manufacturer (person respon-
sible for the "commissioning"), serial number, year of manufacture
and "CE" marking.
END OF THE
10.
PROGRAMMING
PROCEDURE
If the "FORCE" knob is adjusted, the automation's
The red "Error" LED flashes during the automation's
12453