Error Lamp Lights/Blinks
Misfeed (Continuous)
If misfeeding occurs frequently even though the sheets are loaded correctly:
Check
Check whether the front
guide is set against the
edge of the stack too
tightly.
Check the setting of the
feed pressure adjusting
block under the bin.
Check the setting of the
pad pressure adjusting
lever on the left side of
the collator.
Check whether the
sheets being used are
within the specifications
for type and size.
Check whether the stack
in each bin is higher than
28 mm (1.1").
Check whether the feed
roller is stained.
Check whether the feed
roller is worn.
23
Causes and Remedies
Set the front guide so that the guide just
touches the edge of the stack.
21098
40102A1
Check the setting of the feed pressure
adjusting blocks. If a block is set to the nor-
mal position, reset it to the strong position.
Strong
21098
40102B1
Open the transport door and check the set-
ting of the pad pressure adjusting lever. If
the lever is set to the strong (lower) position,
Normal
reset it to the normal (upper) position.
21098
40102C1
Use sheets which are within the specifica-
Within
tions.
Specification
21098
40102D1
Do not load sheets in a bin higher than 28
28 mm (1.1")
mm (1.1").
21098
40102E1
Clean the roller using rubber cleaner.
Clean
21098
40102F1
Replace the feed roller.
Check
21098
40102G1
Page
Page 5
-
-
-
Page 5
Page 30
Page 31