Warnings - TANDBERG D14049.04 Administrator's Manual

Tandberg video communications server administrator guide
Table of Contents

Advertisement

Grey Headline (continued)

Warnings

Warnings occur when an event or configuration change has taken place on the VCS that requires some manual administrator intervention, such as a restart. Warnings may also be raised for hardware
and environmental issues such as faulty disks and fans or high temperatures. The Warnings page (Status > Warnings) provides a list of all the warnings currently in place on your system (and, where
applicable, their proposed resolution).
When there are unacknowledged warnings in place on the VCS, a warning icon
Warning message
An Ethernet interface speed setting has been negotiated to a value other than 1000Mb/s full duplex or 100Mb/s full duplex. This may result in
packet loss over your network
Capacity warning: the number of concurrent non-traversal calls has approached the licensed limit
Capacity warning: the number of concurrent traversal calls has approached the licensed limit
Capacity warning: the number of concurrent Registrations has approached the licensed limit
Cluster name not configured: if FindMe or clustering are in use a cluster name must be defined
Cluster replication error: automatic replication of configuration has been temporarily disabled because an upgrade is in progress
Cluster replication error: cannot find master or this peer's configuration file, manual synchronization of configuration is required
Cluster replication error: configuration master ID is inconsistent, manual synchronization of configuration is required
Cluster replication error: NTP server is not configured
Cluster replication error: the local VCS does not appear in the list of peers
Cluster replication error: the Master peer is unreachable
Cluster replication error: the NTP server is unreachable
Cluster replication error: there was an error during automatic replication of configuration
Cluster replication error: this peer's configuration conflicts with the master's configuration, manual synchronization of configuration is required
Configuration conflict: a domain is in use by the OCS Relay application that has not been configured on the VCS
Configuration conflict: the FindMe mode is set to "On" or "Third Party Manager" but the FindMe option key has been deleted
Configuration warning: expected default link between the Default Subzone and the Cluster Subzone is missing
Configuration warning: expected default link between the Default Subzone and the Default Zone is missing
Configuration warning: expected default link between the Default Subzone and the Traversal Subzone is missing
Overview and
System
Introduction
status
configuration
D14049.07
March 2010
appears at the top right of all pages. The following table lists the warnings that can be raised on the VCS.
Warnings list
VCS
Zones and
Clustering and
configuration
neighbors
peers
Overview
Call
Bandwidth
processing
control
284
TANDBERG
VIDEO COMMUNICATION SERVER
Resolution
Configure
Ethernet parameters
Contact your TANDBERG representative
Contact your TANDBERG representative
Contact your TANDBERG representative
Configure the
cluster name
Wait until the upgrade has completed
View
cluster replication troubleshooting instructions
View
cluster replication troubleshooting instructions
Configure an
NTP server
Check the
list of peers for this cluster
Check the
list of peers for this cluster
Reconfigure the
NTP server
View
cluster replication troubleshooting instructions
View
cluster replication troubleshooting instructions
Reconfigure the
OCS Relay
or view and edit the VCS
SIP domains
Reconfigure
FindMe mode
or reinstall the
Configure
default links
Configure
default links
Configure
default links
Firewall
Applications
Maintenance
traversal
ADMINISTRATOR GUIDE
option key
Appendices

Advertisement

Table of Contents
loading

Table of Contents