Pattern Variable Reference - TANDBERG D14049.04 Administrator's Manual

Tandberg video communications server administrator guide
Table of Contents

Advertisement

Grey Headline (continued)

Pattern variable reference

Overview
The VCS makes use of pattern matching in a
number of its features, namely
Allow Lists and
Deny
Lists,
pre-search transforms
and when
configuring
search rules and zone
transforms.
For each of these pattern matches, the VCS
allows you to use a variable that it will replace
with the current configuration value(s) before
the pattern is checked.
These variables can be used as either or both
of:
all or part of the pattern that is being
searched for
all or part of the string that is replacing the
pattern that was found.
The variables can be used in all types of
patterns, i.e. prefix, suffix, regex and exact.
The table opposite shows the strings that
are valid as variables, and the values they
represent.
You can test whether a pattern will
match a particular alias and be
transformed in the expected way by
using the
Check pattern
page (Maintenance >
Tools > Check pattern).
Overview and
System
Introduction
status
configuration
D14049.07
March 2010
String
Equals current value(s) returned by...
%ip%
xConfiguration Ethernet 1 IP V4 Address
xConfiguration Ethernet 1 IP V6 Address
xConfiguration Ethernet 2 IP V4 Address
xConfiguration Ethernet 2 IP V6 Address
%ipv4%
xConfiguration Ethernet 1 IP V4 Address
xConfiguration Ethernet 2 IP V4 Address
%ipv4 _ 1%
xConfiguration Ethernet 1 IP V4 Address
%ipv4 _ 2%
xConfiguration Ethernet 2 IP V4 Address
%ipv6%
xConfiguration Ethernet 1 IP V6 Address
xConfiguration Ethernet 2 IP V6 Address
%ipv6 _ 1%
xConfiguration Ethernet 1 IP V6 Address
%ipv6 _ 2%
xConfiguration Ethernet 2 IP V6 Address
%localdomains%
xConfiguration SIP Domains Domain 1 Name
...
xConfiguration SIP Domains Domain 20 Name
%localdomain1%
xConfiguration SIP Domains Domain 1 Name
...
...
%localdomain20%
xConfiguration SIP Domains Domain 20 Name
%systemname%
xConfiguration SystemUnit Name
VCS
Zones and
Clustering and
configuration
neighbors
peers
Valid variable strings
When used in a Pattern field
Matches all IPv4 and IPv6 addresses
currently configured on the VCS.
Matches the IPv4 addresses currently
configured on the VCS for LAN 1 and LAN 2.
Matches all IPv4 address currently
configured on the VCS for LAN 1.
Matches all IPv4 address currently
configured on the VCS for LAN 2.
Matches the IPv6 addresses currently
configured on the VCS for LAN 1 and LAN 2.
Matches the IPv6 address currently
configured on the VCS for LAN 1.
Matches the IPv6 address currently
configured on the VCS for LAN 2.
Matches all the SIP domains currently
configured on the VCS.
Matches the specified SIP domain. Up to 20
SIP domains can be configured on the VCS,
and they are identified by an index number
between 1 and 20.
Matches the VCS's System Name.
Call
Bandwidth
processing
control
192
TANDBERG
VIDEO COMMUNICATION SERVER
When used in a Replace field
not applicable
not applicable
Replaces the string with the
LAN 1 IPv4 address.
Replaces the string with the
LAN 2 IPv4 address.
not applicable
Replaces the string with the
LAN 1 IPv6 address.
Replaces the string with the
LAN 2 IPv6 address.
not applicable
Replaces the string with the
specified SIP domain.
Replaces the string with the
VCS's System Name.
Firewall
Applications
Maintenance
traversal
ADMINISTRATOR GUIDE
Appendices

Advertisement

Table of Contents
loading

Table of Contents