5.2.3.3 Example system solution 3
System solution for DHP-AL, DHP-AL Opti.
Figure 26.
Example system solution 3
5.2.4
Connecting cold and hot water lines
1.
Connect the cold water and hot water pipes with all the necessary components according to the connec-
tion diagram for the relevant system.
5.2.5
Connecting the heating system supply and return lines
For information on how flexible hoses should be installed, see Flexible hoses.
1.
Connect the supply pipe with a flexible hose connection and with all the necessary components.
2.
Connect the return pipe with a flexible hose connection and with all the necessary components including a
filter.
3.
Insulate the supply and return lines.
4.
Connect the bleed valve to the outlet (22mm Cu) on the top of the heat pump.
32 – Installation instructions VMBMA1002
Symbol explanation
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot-water
17
Water heater (DHP-AL)
36
Circulation pump
51
Supply line sensor, moved out from heat
pump
72
Additional shunt
77
Reversing valve
80
Shut-off valve
83
Non-return valve
85
Venting valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Strainer
96
Flexible hose
113
Expansion heating system
117
External auxiliary heater
126
Safety valve for temperature and pressure
(only applies to certain models)

Hide quick links: