Connection Heat Transfer Fluid - Danfoss DHP-A Installation Instructions Manual

Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

5.2

Connection heat transfer fluid

5.2.1
System solution 1
In system solution 1 the heat pump can produce both heating and hot water with the compressor and the integra-
ted auxiliary heater. Production of heating and hot water cannot occur at the same time because the exchange
valve for heating/hot water is positioned after the auxiliary heater.
The integrated auxiliary heater carries out peak heating charging (antilegionella function) in those operating
modes that permit auxiliary heat.
For system solution 1, select the factory setting in menu SERVICE\AUX. HEATER\EXTERNAL ADDITION:
EXTERNAL AUX. HEATER = 0 (Off)
REV.V. HOT WATER = INT
5.2.1.1 Example system solution 1
System solution for DHP-H, DHP-H Opti, DHP-H Opti Pro, DHP-C, DHP-A, DHP-A Opti.
Figure 16.
Example system solution 1
Symbol explanation
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot-water
80
Shut-off valve
83
Non-return valve
85
Venting valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Strainer
96
Flexible hose
113
Expansion heating system
126
Safety valve for temperature and pressure (only
applies to certain models)
Installation instructions VMBMA1002 – 23