Menu selection
INTEGRAL DELAY
HGW-SHUNT TIME
HGW INT. BOUND.
HGW INTEGRAL
PULSE WIDTH
62 – Installation instructions VMBMA1002
Meaning
Delay of integral calculation in seconds after the integral value for HGW
has been reached.
The time that the signal is active to open or close the HGW shunt com-
pletely.
Integral value (parameter) for HGW.
Shows the actual value for the HGW integral. Plus indicates that the
shunt opens towards the water heater and minus indicates that the
shunt opens towards the heating system.
How long the plus or minus signal to the shunt is to be high when the
HGW integral has been reached.
Factory setting
10S
(range: 5S / 120S)
35S
(range: 15S / 60S)
60
(range: 10 / 120)
-
0.25S
(range: 0.20S / 1.00S)