Dhp-Al, Dhp-Al Opti - Danfoss DHP-A Installation Instructions Manual

Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

3.7

DHP-AL, DHP-AL Opti

The brine pipes can be connected on either the left or right-hand sides of the heat pump.
1
455
Figure 6.
Dimensions and connections heat pump and water heater
Symbol explanation
Heat pump
1
Brine in, 28 Cu
2
Brine out, during normal operation, 28 Cu
3
Brine out during defrosting to hwh pos 8, 28 Cu
4
Return line from water heater pos 9, 28 Cu
Symbol explanation
Water heater
8
Connection for brine out when defrosting from
pos 3
9
Water heater, return pipe to pos 4
10
Bleed valve, at stainless steel water heater
11
Brine out during defrosting, 28 Cu
12
Hot water line, 22 mm
6
2
4
3
40±10
690
7
5
5
Heating system supply pipe, 22 Cu: 6-10 kW, 28 Cu: 12
kW
6
Heating system return pipe, 22 Cu: 6-10 kW, 28 Cu: 12 kW
7
Lead-in power and sensor lead
13
Cold water line, 22 mm
14
Supply to water heater coil
15
Brine, expansion outlet when outdoor unit is positioned at
high level
16
Lead-in sensor lead
17
Safety valve for temperature and pressure (only applies to
certain models)
15
17
11
9
8
40±10
455
690
Installation instructions VMBMA1002 – 13
16
14
13
12
10