To install the heat pump the front cover must be removed.
1
2
3
Figure 8.
Removing the front cover
1.
Press against the front cover and turn the catch 90° degrees anti-clockwise to release the front cover.
2.
Tilt the front cover outwards.
3.
Lift the front cover upwards to remove it from the heat pump.
4.4

Setting-up the outdoor unit

Note! Applies to DHP-A.
4.4.1
Recommended location
When positioning the outdoor unit, note the following:
Caution! When the outdoor unit is defrosting, water will drip straight down under the unit. The area
around the outdoor unit must therefore be properly drained in order to take the water (approximately 2
litres per defrost).
Caution! The outdoor unit's adjustable stand must be positioned on a secure base such as wooden
sleepers, paving slabs or cast footings.
Note! The outdoor unit does not have to be positioned in any specific direction.
Note! Noise is produced from the outdoor unit when the fan is in operation, remember this when
positioning to reduce disturbance in your own home as well as to any neighbours.