Connect Outdoor Unit, Dhp-A, Dhp-Al; Connect Temperature Sensor Hot Water, Dhp-L; Changing The Language In The Control Computer - Danfoss DHP-A Installation Instructions Manual

Hide thumbs Also See for DHP-A:
Table of Contents

Advertisement

6.5

Connect outdoor unit, DHP-A, DHP-AL

Caution! The power cable may only be connected to the terminal block intended for this purpose. No
other terminal blocks may be used!
1.
Route the power cable through the opening in the top panel of the heat pump to the terminal blocks.
2.
Connect the power cable to the terminal block.
Outdoor unit
1
N/220
2
211
3
213
104
4
218
386
5
387
6
125
N/220
7
9
126
N/220
8
127
Figure 42.
Connection outdoor unit
6.6

Connect temperature sensor hot water, DHP-L

Sensor for hot water and hot water peak from external water heater is connected in the following way to DHP-L,
DHP-L Opti, DHP-L Opti Pro.
1
2
Figure 43.
Connection temperature sensor hot water
6.7

Changing the language in the control computer

If necessary, change the language in the control computer menu system
1.
Ensure that the main circuit breaker is on.
2.
Open the INFORMATION menu.
3.
Change language in the control computer menu INFORMATION -> LANGUAGE - ENGLISH, select language
with + or -.
Heat pump
PE
220/N
211
213
283
104
218
386
387
125
Symbol explanation
1.
2.
311
312
325
326
Symbol explanation
1
Neutral
2
Fan high speed
3
Fan low speed
4
Motor protection fan
5
Defrost sensor
6
Accessories
7
Heating, drip tray
8
Heating cable
9
Accessories
Sensor hot-water
Sensor hot-water top
Installation instructions VMBMA1002 – 41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents