5.2.3.2 Example system solution 3
System solution for DHP-L, DHP-L Opti.
Figure 25.
Example system solution 3
Symbol explanation
1
Heat pump
10
Supply line
11
Return line
12
Cold water
13
Hot-water
18
Water heater
36
Circulation pump
51
Supply line sensor, moved out from heat
pump
72
Additional shunt
77
Reversing valve
80
Shut-off valve
83
Non-return valve
85
Venting valve
86
Safety valve expansion heating system
87
Safety valve cold water 9 bar
89
Vacuum valve
91
Strainer
96
Flexible hose
113
Expansion heating system
117
External auxiliary heater
126
Safety valve for temperature and pressure
(only applies to certain models)