17. PRODUCT DISCONNECTIO N
17.1

MAINS DISCONNECTION

To completely disconnect the system from the mains follow the steps below:
If the Traka Power Supply is connected to a non-switched fused spur, remove the fuse from the spur.
If the Traka Power Supply is wired to a plug and connected to a power outlet outside of the system, disconnect
the plug from the power outlet.
If the Traka Power Supply is wired to a plug and connected to a socket in a power bar inside the lockers,
disconnect the power bar as explained in the following points.
If the system is fitted with a single or multiple power bars and wired to a BS60309-2 'Commando' plug,
disconnect all commando plugs from the sockets.
If the system is fitted with a single or multiple power bars and connected to non-switched fused spurs, remove
the fuses from the spurs.
If the system is fitted with a single or multiple power bars that are wired to plugs and connected to power
outlets, disconnect the plugs from the power outlets.
In the case of a battery being fitted there are two power sources to disconnect before any service or
maintenance work is carried out.
17.2

BATTERY DISCONNECTION

The battery is connected to the Traka Touch PCB on the back of the control panel.
For Battery disconnection, carefully disconnect the connector from the Traka Touch PCB.
WARNING:
Never disconnect the wires from the green connector whilst the cable is still connected to the
battery terminals.