Front panel description
One copper Gigabit Ethernet 1000 uplink/access port
●
Versions of the MM314 media module with Material Code 700384 (C/S:2.0) require Avaya CM
version 2.0 and higher, and G350 firmware version 25.0.0 and higher.
Figure 29: The MM314 media module front panel
MM314 ports
The MM314's 24 10/100 Base-T Ethernet ports are located on the front panel and are labeled 1
through 24. The MM314's copper Gigabit Ethernet port is located on the left of the front panel
and is labeled 51. You can connect to these ports using a straight network cable with an RJ-45
connector, or a crossover cable with an RJ-45 connector.
MM314 alarm LED
The MM314's alarm (ALM) LED is located on the left of the front panel. The ALM LED indicates
that an alarm is present in the module.
Table 9: MM314 System LED
LED
ALM
116 Installation and Upgrades for the Avaya G350 Media Gateway
Name
Color
Alarm
Red
Meaning
OFF - The software turns this
●
LED off if BIST has passed and
48V PS is active
ON - Module is initializing, or an
●
alarm state exists on an interface,
or there is a mismatch between
Communication Manager
configuration and the Media
Module.
BLINK - There is a mismatch
●
between MV configuration and
this Media Module.