GD1 – Installation Guide
1.2.2 – M
ULTIAXIS CONFIGURATION
MULTIAXIS CONFIGURATION WITH INTEGRATED 230 V
TO A RATED POWER < 4 kW
A1
Power supply
+
filtre
+
braking
resistor
GD1- 230/05 to 30 - PS-R
MULTIAXIS CONFIGURATION WITH INTEGRATED 400/480 V
UP TO A RATED POWER < 7 kW
A1
Power supply
+
filtre
+
braking
resistor
GD1- 400/05 to 20 - PS-R
Part 1 – Chapter 1 – General description
A2
GD1- 230/05 to 20 - 00-0
Connect the actuators from A1 to An in the
decreasing order of their current ratings
A2
GD1- 400/05 to 20 - 00-0
Connect the actuators from A1 to An in the
decreasing order of their current ratings
SINGLE-PHASE POWER SUPPLY UP
AC
An
A3
(n max = 6)
THREE-PHASE POWER SUPPLY
AC
An
A3
(n max = 6)
DC bus 320 V
DC
DC bus 600 V
DC