Specification Of The Logic Inputs Inx; Specification Of The Aok Logic Output On Optorelay - Infranor Gem Drive GD1 Series Installation Manual

Table of Contents

Advertisement

GD1 – Installation Guide
3.5.1 – S
PECIFICATION OF THE LOGIC INPUTS
These optocoupled inputs operate in positive logic.
The input voltage corresponding to level 1 must be between 18 V and 30 V.
3.5.2 – S
PECIFICATION OF THE
Opto-relay polarised contact. Closed if drive OK, open if fault: the polarity AOK+ positive potential with regard to
AOK- must be observed.
Pmax = 10 W with Umax = 50 V – Imax = 300 mA.
The AOK output is not made of a dry contact. The polarity must be observed in the load
connection. The serial connection of several AOK signals must also observe this polarity (see
diagram below).
22
INX
8,2 kΩ
Logic input
100 kΩ
0V external
(*): 100 pF for Index and Capture inputs
AOK
LOGIC OUTPUT ON OPTORELAY
5 V
+24V
AOK+
AOK-
AOK+
AXIS 1
AXIS 2
3,3 V
100 nF*
Bidirectional
Transil
AOK+
AOK-
AOK-
AXIS 3
PLC
input
Part 1 – Chapter 3 – Inputs-Outputs
AOK+
X2-32
AOK-
X2-31

Advertisement

Table of Contents
loading