D Wiring the system cable
1. Remove the 4 bolts on the bottom of the scanner
body using the supplied allen wrench (1), and
open the top cover. (2)
2
2. Remove 2 screws and cable clamp.
3. Remove the sealing nut outside the scanner unit.
4. Pass the system cable through the sealing nut,
sealing tube, scanner body, and the cable clamp
base.
Sealing nut
To the
display unit
System
cable
When using an optional OPC-2340 system cable:
Strip off a part of the outer sheath of the system
cable, as shown below.
18±2 mm
(0.71±0.08 in)
Display ←
unit
Strip off
CAUTION: DO NOT cut the inner shield wire when
stripping off the outer sheath.
1
Screw
Cable
clamp
Sealing tube Cable clamp
base
Scanner body
410±5 mm
(16.14±0.2 in)
→ Scanner
unit
INSTALLATION AND CONNECTIONS
5. Connect the system cable to the scanner unit.
1 Pass the power cables (black and red) of
the system cable through the looped cable
tie, and then connect them to the power unit
connectors.
2 Carefully insert the PA cable (black and white)
connector into the PA unit connector, as shown
below.
3 Secure the looped PA cable with the looped
cable tie.
6. Ground the system cable to the chassis with the
screw, as shown below.
7. Fix the system cable with the cable clamp near the
sealing connector and two screws.
Attach the ferrite EMI filter close to the sealing
connector of the system cable, and then secure
the cable tie beside the ferrite EMI filter, as shown
below.
9
1
Cable tie
Power
cable
3
PA
cable
2
Ground wire
Screw
Cable clamp
Ferrite
EMI filter
Cable tie
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
50