Measuring variants
2.3 Measure workpiece (milling)
Parameters
G code program
Parameters Description
PL
Measuring plane (G17 - G19)
Calibration data set (1 - 12)
F
Calibration and measuring
feedrate
Parameters
Description
∅
Ring diameter
DFA
Measurement path
TSA
Safe area for the measurement result
NOTICE
When the calibration is performed for the first time, the default setting in the data field of the
probe is still "0". For this reason, the TSA parameter must be programmed > probe ball
radius to avoid the alarm "Safe area exceeded".
88
ShopMill program
Unit
Parameters Description
-
T
-
D
Distance/
min
F
X
Y
Z
Name of the probe
Cutting edge number (1 - 9)
Calibration data set (1 - 12)
Calibration and measuring
feedrate
Start point X of the measurement
Start point Y of the measurement
Start point Z of the measurement
Programming Manual, 02/2011, 6FC5398-4BP40-0BA0
Unit
-
-
-
mm/min
mm
mm
mm
Unit
mm
mm
mm
Measuring cycles