Electrical system
Fan activation
Lambda probe heater 1
Fuel manifold test
Injector control
Headlights relay
Stepper
Fuel pump
General warning light
Diagnostic tool - Errors screen page
This display shows potential errors detected in the vehicle (ATT) or stored in the control unit
(MEM) and it allows to check error clearing (STO).
Diagnostic tool - Electrical errors
Air pressure sensor P0105 - short circuit to positive / open circuit, short circuit to negative, signal not
valid
Cause of error
Malfunction of sensor inside the control unit
Troubleshooting
Replace the control unit
Air temperature sensor P0110 - short circuit to positive, open circuit / short circuit to negative
Cause of error
Malfunction of sensor inside the control unit
Troubleshooting
Replace the control unit
Error EEPROM P0601 - circuit not working
Cause of error
The instrument panel does not indicate the presence of this error even in the ATT status
Troubleshooting
Replace the engine control unit
Saved data file (for safety) P1607 - filled
Cause of error
This indication appears only if the Level 2 safety has reset the engine (C gravity). The
in- strument panel does not indicate the presence of this error even in the ATT status.
Troubleshooting
 Replace the engine control unit